Fault 0001 may occur when the elevator takes more than 45 seconds to travel between floors.
Three common causes should be checked:
Incorrect Speed Settings: Improper speed or deceleration parameters may cause abnormal operation, especially in multi-floor travel.
Excessive Floor Distance: On K20K series elevators, check whether the floor distance exceeds 5 meters.
Electrical Contact Issues: Faulty relay contacts or poor contact at the main contactor may trigger the fault.
Troubleshooting Tip: Check floor travel speed, adjust deceleration parameters, and inspect the relevant relay and contactor connections.
#KONEElevator #ElevatorFault #ElevatorTroubleshooting #ElevatorMaintenance