When commissioning the STEP AS380 elevator controller, correct parameter settings are essential for successful shaft self-learning and smooth elevator operation.
Key points to check:
Input Settings: Configure F25–F28 according to the actual wiring and input signal types.
Service Floors: Set F29 according to the floors served by the elevator.
Motor Parameters: Set F201–F211 according to the motor and encoder specifications.
Shaft Self-Learning: Set F165 to 8, check the required signals, then change the self-learning command from LRR 00 to LRR 01 and confirm.
Ride Comfort: Adjust acceleration and deceleration slopes and PID parameters as needed.
Technical Note: Verify all settings against the actual installation and follow proper safety procedures before commissioning.