STEP AS380 Elevator Controller | Commissioning Tips

Oct 19th,2026 58 Views

When commissioning the STEP AS380 elevator controller, correct parameter settings are essential for successful shaft self-learning and smooth elevator operation.

Key points to check:

Input Settings: Configure F25–F28 according to the actual wiring and input signal types.

Service Floors: Set F29 according to the floors served by the elevator.

Motor Parameters: Set F201–F211 according to the motor and encoder specifications.

Shaft Self-Learning: Set F165 to 8, check the required signals, then change the self-learning command from LRR 00 to LRR 01 and confirm.

Ride Comfort: Adjust acceleration and deceleration slopes and PID parameters as needed.

Technical Note: Verify all settings against the actual installation and follow proper safety procedures before commissioning.

#ElevatorTechnology #STEPAS380 #ElevatorMaintenance #ElevatorCommissioning