Accurate weighing system adjustment is essential for proper load detection in Mitsubishi HOPE-II elevators. Here are the key procedures for installation, commissioning, and maintenance.

🔧 Preparation & Adjustment

Ensure the elevator is ready for operation, with a 45–50% balance coefficient.

Check rope tension and weighing sensor installation.

Adjust the differential transformer spring length to 37.5 mm.

⚙️ Load Calibration

No-load: Set the MON switch to “1” and use “2” to check the empty-load data.

Half-load: Add 50% rated load and record the corresponding data.

Data Storage: Use the LDO/LDI switch to save the calibration data.

🔍 Overload Adjustment

Place 110% of the rated load in the car.

Adjust the WGH potentiometer until the overload detector activates.

💡 Maintenance Tip

Recalibration may be required after traction rope replacement, rope tension adjustment, weighing component replacement, or significant weighing data deviation.