🔧 Basic Settings (1500 Function)

BF01/02: CANBUS display / setting

BF03/04: Car load display mode

BF05/06: Set to 004 (linear sensor)

BF07/08: No-load sensing distance

BF09/0A: Rated load

⚙️ Zero Adjustment

Ensure no load in car and stable installation

Enter BF0C → adjust sensor position

All LED indicators off (max 1 allowed)

Save and exit (BF00)

📊 Load Learning

Must complete zero adjustment first

Add rated load into car

Enter BF0F → input 110% load value

Save and test overload function

🔍 Maintenance Checks

Verify zero point accuracy (BF0C / P50)

Check sensor, power (DC24V), and signal (≈2.5V)

Ensure wiring, connectors, and installation are secure

💡 Key Note
Accurate zero setting + correct load learning = reliable overload performance

#ElevatorMaintenance #Thyssen #LMS1 #Troubleshooting