• Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03

Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03

Elevator Parts PCB
Part No: KM713140G04/KM713140G01/KM713140G02/KM713140G03/KM713140G05/KM713140G06/KM713140G07/KM713140G08/KM713140H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03
  • Elevator PCB Elevator Power Supply Board KM713140G04/1/2/3/5/6/7/8/H03

Product Overview

The KONE elevator power supply board sits in the control cabinet and holds the supply steady for the controller and everything wired to it. Because the cabinet layout has not changed, a replacement goes back onto the same mounting studs and takes the same terminal blocks, which is why a board swap is normally the shortest route back into service. The range covered here is the KM713140 series in its G01 to G08 and H03 forms, with the G04 revision shown on this listing. That spread is not padding. The same cabinet model can carry a different revision depending on the year it was built, and the suffix printed on the failed board is the only dependable way to order the right one. Every elevator PCB we send out is brand-new original stock, not a pulled or repaired unit. Buyers here are usually in one of three situations: a maintenance contractor with a car standing idle, a distributor restocking a fast-moving control item, or a retrofit engineer working through older equipment. Whether you buy the way an elevator spare parts manufacturer buys, against a build list and in quantities, or you are fitting a single board on site at short notice, the revision check is what decides whether the order is right.

Board Construction & Layout

  • Screw-mounted aluminium heat sink. The power devices sit under a finned heat sink along one edge of the board, clamped down with screws. Keep the old board's mounting screws with it, because the replacement goes back on the same studs and the same hardware.
  • Capacitors and glass-tube fuses on the top face. Large electrolytic capacitors stand behind the heat sink and the fuses sit in holders beside them. On a failed board these are the areas worth a close look, and they are also what a technician re-checks after fitting.
  • Orange terminal blocks. Supply in, supply out and the signal connections all land on colour-coded screw and plug-in blocks, so the wiring comes off and goes back position by position rather than as a loom.
  • Through-hole build with a green solder mask. A conventional through-hole layout with a glossy green mask and joints visible on the solder side, so a cracked joint or a heat mark shows up under a lamp.
  • Metal mounting bracket. An L-shaped bracket carries the mounting points and takes the load when the KONE control cabinet board is screwed into place, rather than the corners of the PCB.
  • A board you can inspect. Nothing is potted or hidden. The elevator components that matter, from the capacitors and fuses to the terminal blocks, are all reachable on the top face, so incoming inspection is a visual job.
  • Built to the original pattern. Every elevator board we ship is an original unit, not a reworked or re-marked one: component positions, connector types and mounting holes match what came out of the cabinet, exactly as the elevator parts manufacturer specified them.
Front and solder-side view of the circuit board assembly.

Label & Revision Matching

  1. Read the label before you touch anything. The reference and the board revision are printed together on the board's sticker, next to a barcode. Write both down exactly as they appear; G04 and G05 are different order lines.
  2. Photograph the elevator PCB in place. One wide shot of the connector layout and one close-up of the label is enough. The wide shot doubles as your reassembly guide when the new board goes in.
  3. Send the photo with your enquiry. An elevator parts supplier who handles this family every week will read the suffix straight off the image and flag a mismatch before anything is packed for you.
  4. Check the wiring as well as the number. If the old board has been replaced before with a different revision, the cable set may already have been adapted. Tell us and we will look at the connector side with you.
  5. Fall back to the paperwork. If the label is burnt or missing, the board reference is usually recorded in the controller documentation, the cabinet drawing or the maintenance file. Send those instead, together with the controller type.
  6. Do not order by the commissioning date. Two cars handed over in the same month can carry different revisions, and the age of the lift tells you nothing about which one is inside the cabinet.

Board Replacement Procedure

  1. Confirm the fault is on the board, not ahead of it. Before the old unit comes out, check the incoming supply at the cabinet terminals, the upstream breaker and any fuse feeding the board. A power supply board that has already been destroyed by a supply fault will be destroyed again, and the second one is not a warranty matter.
  2. Isolate and lock off. Open the main switch, lock or tag the isolator, and give the electrolytic capacitors on the old elevator board time to discharge before you put a hand anywhere near it. Work inside the control cabinet stays with a qualified technician.
  3. Record everything before you remove anything. Photograph the connector layout in place, write down the board revision printed on the label, and note the fault codes or symptoms the controller was showing. Those notes are what a later diagnosis and any warranty conversation are built on.
  4. Label the connectors, then take them off. Mark each plug and screw terminal with its position before the first one comes loose, using tape flags or a marker straight on the block. Wiring goes back position by position rather than as a loom, and the photograph is your fallback when a flag drops off.
  5. Keep the mounting screws and the old board. The power supply board replacement goes back on the same studs with the same hardware, so nothing needs drilling or adapting. Bag the old board in the anti-static wrap the new one arrived in and keep it until the lift has completed a full run — it is also the reference unit if a claim has to be raised.
  6. Treat the new board as static-sensitive. Leave it in its bag until the cabinet is ready, discharge yourself against the cabinet frame before handling it, and hold it by the edges only. Do not rest it on the heat sink or on a bare metal surface, and do not flex it while lining up the mounting holes.
  7. Refit, then check before powering up. Seat every connector fully, confirm each plug matches the position you recorded, check that the fuses are sitting properly in their holders, and compare the new elevator power supply board against the old one so nothing has been left off. Close the cabinet, restore the supply and check the rails and controller start-up against the values in the controller documentation.
  8. Run the lift before signing off. Let the controller boot, clear the fault log, and cycle the car through a full run with the doors operating. Final commissioning and the lift's safety checks stay with a qualified technician, as they do with any elevator components fitted in the control cabinet.

Replacement Scenarios

  • Controller dead after a power event. A supply dip or a surge takes the board out and the controller will not boot. Ruling the board in or out is usually the first job, and having one on the shelf turns a two-day wait into an afternoon.
  • Lift stopped and refusing to reset. Intermittent stops that clear themselves and come back point at a supply that is fading rather than dead. A power supply board replacement takes that variable out before anyone starts chasing door and brake faults.
  • Distributor stock cover. A revision that fails once on a site tends to appear again elsewhere in the same fleet. Stock that mirrors how the elevator spare parts manufacturer keeps each revision separate protects the counter from wrong-part returns.
  • Retrofit and modernisation work. Mixed-age equipment pulls boards from several build years into one project, so a controller replacement mid-project can need two different revisions on the same site.
  • Van and workshop stock. Service firms keep one on the van and one on the bench. The calculation is the same one an elevator parts manufacturer makes when deciding what to hold: the part is cheaper than the lost day.
  • Aging cabinets. A KONE control cabinet board runs hotter as the cabinet ages, with fans slowing and filters clogging, and the elevator components around the supply are usually still serviceable when the board itself is not.
  • The board family runs through G01, G02, G03, G04, G05, G06, G07, G08 and an H03 reference, and the suffix is a build identifier rather than a stock code. The rule to hold on to is that G04 and G05 cannot be used universally: one will not stand in for the other, whatever the connector layout looks like from above. Fit the revision printed on the elevator board you are taking out. That is how an elevator parts manufacturer marks a change in the build, and it is why a photograph of the old label settles the question faster than any description of the cabinet. The rest of the G-series and the H03 board are ordered through the same family, so if your unit carries one of the other suffixes, tell us which and we will quote that reference rather than this one. For distributors, the practical consequence is stock cover. Holding one revision and assuming it covers the fleet is how a second breakdown becomes a second week of downtime. Stockists who mirror the way an elevator spare parts manufacturer keeps each revision as its own part number get far fewer wrong-part returns.

Specifications

FeatureBrand new, original
Brand NameOther
TypeElevator Parts
Product NameElevator PCB
Model NumberKM713140G04
Series CoverageG01 / G02 / G03 / G05 / G06 / G07 / G08 / H03
Product Weight0.4 kg
Supplied AsComplete board assembly with heat sink, capacitors, fuses and terminal blocks fitted
ApplicationElevator power supply board for the control cabinet
Payment TermsT/T,Western Union
Delivery1-3 Working Days
Warranty TimeOne Year
TransportationDHL/TNT/FEDEX/UPS
MOQ1PC

Ordering & Delivery

  1. Send the reference and a photo. Quote the number and revision from your old board. We check it against what we hold before the order is confirmed and tell you straight away if the suffix does not match.
  2. Order as few or as many as you need. The minimum order is 1PC, so a one-off repair and a distributor restock go through the same process.
  3. Payment terms. This part is invoiced on T/T or Western Union. L/C, Visa, Mastercard, e-checking and PayPal are also accepted across our range.
  4. Packing. Boards travel in a carton or a wooden case, depending on the size of the consignment. Tell us if the elevator board is being consolidated with other items and we will pack the shipment as one.
  5. Delivery. In-stock boards are dispatched in 1-3 working days, by DHL, TNT, FedEx or UPS.
  6. Warranty. Every board carries a one-year warranty. If a fault shows up inside that period, the board reference and your original order details are what we need to look at it with you.
  7. Check on arrival. Compare the new board with the old one before you fit it: revision, connector layout and mounting holes — the three points an elevator spare parts manufacturer checks before dispatch — and that nothing has shifted among the elevator components in the packing.

Technical Support & Model Matching

Choosing the right variant is the hardest part of a replacement order, so our technical team starts from what you already have: a nameplate photo, the markings on the old part, or the part number exactly as it appears in your manual. We match it against the brands and series we supply, point out the suffixes and revisions that will not interchange, and confirm by email before dispatch. After delivery our team stays reachable for fault-finding and practical guidance on fitting the part you ordered. Every item we ship carries a one-year warranty.

FAQ

Will a G05 board work in place of this G04?

No. G04 and G05 cannot be used universally, and fitting the wrong one will not bring the lift back. The revision letter is part of the part number rather than a batch mark, so order the revision printed on the board you are removing. If your unit carries G05, tell us and we will quote that reference instead.

Does the board arrive with the heat sink and terminal blocks already fitted?

Yes. It arrives as the complete KONE control cabinet board assembly shown, with the aluminium heat sink, electrolytic capacitors, fuse holders and orange terminal blocks already in place. Nothing has to be transferred from the old board except the wiring itself.

Is this a brand-new board or a refurbished one?

Brand new and original. It is not a pulled board and not a repaired one: the solder side, the component markings and the printed reference, including the board revision, all match the original build. Condition is the first line of the specification for exactly that reason.

Can a technician replace it on site?

Yes, at board level. Isolate the cabinet supply, photograph the connector layout, and move the wiring across block by block before the old board leaves the cabinet. The power supply board replacement mounts on the existing studs with no drilling or adaptation. Commissioning and the lift's safety checks stay with a qualified technician, as they do for any control-cabinet work.

The label on my old board is burnt. How do I identify the revision?

Look in the controller documentation, the cabinet drawing or the maintenance file, where the board reference is normally recorded. If nothing survives, send a clear photo of the connector side, the cabinet interior and the controller type, and we will work it out with you before you order.

Do you supply the other revisions in the same family?

Yes. G01, G02, G03, G05, G06, G07, G08 and H03 are all ordered through the same family. Tell us the suffix printed on your unit and we will confirm what we can supply. That check is basic work for an elevator parts supplier, and it is the one step that stops a wrong board arriving.

How can I tell the board is original and not a copy?

The giveaways are on the solder side and on the label: joint quality, component markings and the printed reference all have to line up. An elevator parts manufacturer builds to a fixed layout, while a copy drifts between batches. If you want to see the actual unit before it ships, ask your sales contact for close-up photos.